(ii) each public pool and spa in the United States with a single main drain other than an unblockable drain shall be equipped, at a minimum, with 1 or more of the following devices or systems designed to prevent entrapment by pool or spa drains that meets the requirements of subparagraph (B):
(I) Safety vacuum release system A safety vacuum release system which ceases operation of the pump, reverses the circulation flow, or otherwise provides a vacuum release at a suction outlet when a blockage is detected, that has been tested by an independent third party and found to conform to ASME/ANSI standard A112.19.17 or ASTM standard F2387.
(II) Suction-limiting vent system A suction-limiting vent system with a tamper-resistant atmospheric opening.
(III) Gravity drainage system A gravity drainage system that utilizes a collector tank.
(IV) Automatic pump shut-off system An automatic pump shut-off system.
(V) Drain disablement A device or system that disables the drain.
(VI) Other systems Any other system determined by the Commission to be equally effective as, or better than, the systems described in subclauses (I) through (V) of this clause at preventing or eliminating the risk of injury or death associated with pool drainage systems.